- Digital Multimeter
- Analogue Multimeter
- Digital Clamp Meter
- Pen Type Digital Multimeter
- Digital Insulation Tester
- Analogue Insulation Tester
- Pocket Size Digital Multimeter
- Power meter
- Thermometer
- Volt Alert
- Voltage Tester
- Wireless Meter
- Moisture Meter
- Digital Earth Loop Meter
- Automotive Digital Multimeter
- Cable Tester
- Leakage Clamp Meter
- Measuring Instruments
- Soldering Irons and Switches
- Audio Equipments
- Data Logger
- Air Tester
- Clamp Sensors
- Earth Testers
- Laser Distance Meter
- LUX Meter
- Multi Function Testers
- Phase indicators
- RCD/PAT Testers
- Sound Meter
- Storage Cabinet
- Strength Meter
- Test Lead Set
Pacific Radio (M) Sdn Bhd
[16370-U]
80, Jalan Pasar, Pudu,
55100 Kuala Lumpur,
Malaysia.
+603-9221 8631 (6 Lines)
+603-9221 4216
+603-9221 3867
+6018-208 2618
+603-9221 8630
+603-9223 4109
Pacific Electronic (S) Pte Ltd
1 Rochor Canal Road,
#01-10/11/12,
Sim Lim Square,
Singapore 188504.
1 Rochor Canal Road,
#01-10/11/12,
Sim Lim Square,
Singapore 188504.
+65-6294 0851
+65-6337 1132
+65-6339 5884
+65-6337 1132
+65-6339 5884
+65-6339 8454
+65-6338 3609
+65-6338 3609
Fluke v3000 FC Wireless AC Voltage Module
Specifications | |||
Range1 | Resolution | Accuracy2,3,4 | |
45 Hz to 500 Hz | 500 Hz to 1 kHz | ||
6.000 V | 0.001 V | 1.0 % + 3 | 2.0 % + 3 |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V | ||
1 All ac voltage ranges are specified from 1 % of range to 100 % of range. 2 Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V. 3 For non-sinusoidial waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. 4 Do not exceed 106 V-Hz. |
General Specifications | |||
LCD w/backlight | 3½ digits, 6000 counts, updates 4/sec | ||
Battery type | 2 AA, NEDA 15 A, IEC LR6 | ||
Battery life | 400 Hours | ||
Memory | Record up to 65000 readings | ||
RF communications | 2.4 GHZ ISM Band | ||
RF communication range |
Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
||
Operating temperature | -10 °C to +50 °C | ||
Storage temperature | -40 °C to +60 °C | ||
Temperature coefficient | 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) | ||
Operating humidity | 90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C | ||
Altitude |
Operating: 2,000 m Storage: 12,000 m |
||
EMC | EN 61326-1:2006 | ||
Safety compliance |
ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
||
Safety rating | CAT IV 600 V, CAT III 1000 V | ||
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | ||
Ingress Protection (IP) rating | IP42 | ||
Pollution Degree | 2 | ||
Size (HxWxD) | 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) | ||
Weight | .22 kg (8 oz) |