- Digital Multimeter
- Analogue Multimeter
- Digital Clamp Meter
- Pen Type Digital Multimeter
- Digital Insulation Tester
- Analogue Insulation Tester
- Pocket Size Digital Multimeter
- Power meter
- Thermometer
- Volt Alert
- Voltage Tester
- Wireless Meter
- Moisture Meter
- Digital Earth Loop Meter
- Automotive Digital Multimeter
- Cable Tester
- Leakage Clamp Meter
- Measuring Instruments
- Soldering Irons and Switches
- Audio Equipments
- Data Logger
- Air Tester
- Clamp Sensors
- Earth Testers
- Laser Distance Meter
- LUX Meter
- Multi Function Testers
- Phase indicators
- RCD/PAT Testers
- Sound Meter
- Storage Cabinet
- Strength Meter
- Test Lead Set
Pacific Radio (M) Sdn Bhd
[16370-U]
80, Jalan Pasar, Pudu,
55100 Kuala Lumpur,
Malaysia.
+603-9221 8631 (6 Lines)
+603-9221 4216
+603-9221 3867
+6018-208 2618
+603-9221 8630
+603-9223 4109
Pacific Electronic (S) Pte Ltd
1 Rochor Canal Road,
#01-10/11/12,
Sim Lim Square,
Singapore 188504.
1 Rochor Canal Road,
#01-10/11/12,
Sim Lim Square,
Singapore 188504.
+65-6294 0851
+65-6337 1132
+65-6339 5884
+65-6337 1132
+65-6339 5884
+65-6339 8454
+65-6338 3609
+65-6338 3609
GRAPTECH GL100 COMPACT DATA LOGGER
GL100
Specifications
GL100-WL, GL100-N main unit specifications
Item | Description | |
---|---|---|
Number of channels | Varies by the input module used, and measurement type is fixed with each input module | |
Input method, Type of input terminal | ||
Output signal | Alarm (1 channel), solid state switch with optical isolation (Optocoupler, Max. load is the 30 V, 50 mA) | |
Interface to PC | USB (micro USB B type connector), Wireless LAN (WLAN) in GL100-WL | |
Wireless LAN (in GL100-WL) |
Standards: IEEE802.11b, Communication distance: approx. 40 m * It varies by the condition of the LAN. Real-time transfer rate is up to 500ms. The WLAN is able to disable. (It is enabled in the factory default setting) |
|
Storage device |
Built-in memory: RAM (Approx. 4.9 MB) External memory: microSD memory card * Maximum file size for captured data is 1.9MB. It is recommended to use the microSD memory card that supports sleep mode. (Example: TS4GUSDHC4, made by Transcend) |
|
Display |
LCD (backlit monochrome, graphical type 128 x 64 dots) Contents: Captured data and Setting menu (Stored data is not able to replay. It is able to replay using the PC application software.) |
|
Functions |
• Real-time data capturing • Display the captured data value to the LCD in real-time and save the monitoring values • Set conditions using the Menu setting |
|
While using USB port: • Output captured data in real-time • Output the saved data from the internal memory • Full control of the GL100 from the PC application software |
||
While using Wireless LAN (in GL100-WL): • Output captured data in real-time • Output the saved data from the internal memory • Full control of the GL100 from the PC application software • Simple control of the GL100 from the application software of Smart Device • Send warnings via the e-mail |
||
Alarm |
• Action Outputs the signal when the measuring data reaches the present conditions of alarm • Source Level of measuring data • Detecting method Condition: Higher or lower (signal is higher or lower than the threshold) Combination: OR |
|
Trigger |
• Action Start or stop the recording of captured data by trigger • Source Start trigger: OFF, Level (*), Alarm, or Date Stop trigger: OFF, Level (*), Alarm * Level trigger is available in the analog input of the GS-4VT, GS-4TSR, and GS-3AT module. • Detecting method of the Level (*) Condition: Rising or Falling (signal is passed through the threshold) Combination: OR or AND |
|
Dustproof and waterproof |
IP54 compatible (*) * It is effective only in the condition that the input module is set to the GL100 and then the covers of connector and battery are closed. It is recommended to replace the packing of cover in periodically. |
|
Power source |
• Alkaline battery (AA size x 2) • USB bus-power (5V, 200 mA) (*) * When AC adapter for USB device is used, the required power capacity is 5V, 1A. Battery and AC adapter is not included. |
|
Operating environment |
Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) |
|
External dimension [W x D x H] | Approx. 66 x 100 x 27 mm (exclude protrusion) | |
Weight | GL100-N: Approx. 125 g, GL100-WL: Approx. 130 £ç |
Temperature & Humidity sensor (GS-TH) input module
Item | Description | |
---|---|---|
Type of measurement | Actual measuring | Temperature and Humidity |
Calculated value | Dew-point temperature and Accumulated temperature (The temperature will be accumulated during it is higher or lower than the reference temperature.) | |
Method of measurement | C-MOS sensor | |
Measuring range | Temperature | -20 to 85 °C |
Humidity | 0.0 to 100.0 % RH | |
Accuracy | Temperature |
-20 ≤ TS < 0: ± 0.8 °C 0 ≤ TS ≤ 60: ± 0.5 °C 60 < TS ≤ 85: ± 0.8 °C |
Humidity |
at 25 °C Measuring 0 to 10 % RH: ± 10% RH Measuring 10 to 20 % RH: ± 8% RH Measuring 20 to 80 % RH: ± 5% RH Measuring 80 to 90 % RH: ± 8% RH Measuring 90 to 100 % RH: ± 10% RH |
|
Response |
Temperature, Humidity: Approx. 100 seconds (Time to reach 63%, at 25 °C and air flow 1 m/s) * It varies by environment condition. |
|
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Unit of temperature measurement | Switchable °C and °F | |
Water resistance | Protect by waterproof filter at the sensing part | |
Operating environment | Within temperature and humidity measurement range (When sensor is attached directly to the GL100, it is the same specifications as the GL100.) | |
External dimension [W x D x H] | Approx. 15 x 45 x 10 mm (exclude protrusion) | |
Weight | Approx. 14 g |
Acceleration & Temperature sensor (GS-3AT) input module
Item | Description | |
---|---|---|
Type of measurement | Tri-axial aceleration (X-, Y-, Z-axis) and Temperature | |
Measuring range | Acceleration | ±2 G (20m/s2), ±5 G (50m/s2), ±10 G (10m/s2) |
Temperature | -10 to 50 °C (using C-MOS sensor) | |
Accuracy | Acceleration | ±2 % of F.S. (including non linearity) |
Temperature | -10 ≤ TS < 50: ± 1.0 °C | |
Response (acceleration measurement) | 0 Hz to 100 Hz | |
Measuring mode | Memory, or Direct mode | |
Memory capacity | 16, 32, 64, 128 k Samples (for memory mode) | |
Pre-trigger | 10, 25, 50, 100 % of selected memory capacity, and OFF (function is available for memory mode) | |
Sampling interval |
Memory mode: 5, 10, 20, 50, 100 ms Direct mode: 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes |
|
Calculation function (in Direct mode) |
Function: The data is captured in every 5ms interval, and then the result of calculation between selected interval will be saved. Type of calculation: Average, Peak, RMS, or OFF (selected one value will be saved) |
|
Unit of temperature measurement | Switchable °C and °F | |
Offset adjustment function | OFF, ON (sets the static acceleration value of current to zero) | |
Dustproof and waterproof | IP54 | |
Length of cable | Approx. 200 mm | |
Operating environment |
Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) |
|
External dimension [W x D x H] | Approx. 51 x 36 x 20 mm (exclude protrusion) | |
Weight | Approx. 64 g |
Illuminance & Ultraviolet sensor (GS-LXUV) input module
Item | Description | |
---|---|---|
Type of measurement | Actual measuring | Illuminance and UV intensity |
Calculated value | Accumulated illuminance and Accumulated UV intensity | |
Measuring range | Illuminance | 0 lx to 200 k lx |
UV intensity | 0 to 30 mW/cm2 | |
Measuring accuracy | Illuminance | ±5 % at 25 °C (Temperature characteristic: 5 % at 10 °C to 40 °C) |
UV intensity | ±5 % at 25 °C (Temperature characteristic: 5 % at 10 °C to 40 °C) | |
Response | 1 ms or less | |
Accumulating function | Illuminance | 0 to 99999 k lxh (Accumulated value is reset by starting the data recording or pressing the QUIT key.) |
UV intensity | 0 to 99999 mW/cm2h (Accumulated value is reset by starting the data recording or pressing the QUIT key.) | |
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Length of cable | Approx. 200 mm | |
Operating environment |
Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) |
|
External dimension [W x D x H] | Approx. 46 x 66 x 19 mm (exclude protrusion) | |
Weight | Approx. 65 g |
Carbon dioxide (CO2) sensor (GS-CO2) input module
Item | Description | |
---|---|---|
Type of measurement | Carbon dioxide concentration | |
Method of measurement | NDIR (Non Dispersive Infra-red) | |
Measuring range | 0 to 9999 ppm | |
Measuring accuracy | ±0.5 % of reading + 30 ppm (in range of 0 to 5000 ppm) | |
Response | 3 minutes or less | |
Sampling interval |
0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes (Sensing of carbon dioxide is done at interval of 2 seconds or slower. When sampling is selected to 0.5 or 1 second, the same value is recorded in each time and then value is updated every 2 seconds.) |
|
Length of cable | Approx. 200 mm | |
Operating environment |
Temperature: 0 °C to 50 °C Humidity: up to 80 % RH (non condensed) |
|
External dimension [W x D x H] | Approx. 66 x 100 x 25 mm (exclude protrusion) | |
Weight | Approx. 99 g |
AC Current sensor Adapter (GS-DPA-AC) input module & AC Current sensor
Item | Description | |
---|---|---|
Type of measurement | Actual measuring | Current (using optional AC current sensor) |
Calculated value | Power, Accumulated power (Electric energy) | |
Type of sensor | Clamp-on current probe (optional) | |
Application circuit | Single-phase two-wire, Single-phase three-wire, or Three-phase three-wire | |
Number of sensor | Two (2) sensors are able to connect (using the same type of sensor and the power system) | |
Method of measurement | Scans channels (sensors), Non-isolated input, using RMS converter | |
Measuring range | 50, 100, 200 A RMS (varies by the sensor) | |
Applicable frequency | 50 or 60 Hz | |
Measuring accuracy | ±2 % of full sale ± 1 digit (at temperature 23 °C, and within rated current and frequency) | |
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Length of cable | Approx. 200 mm | |
Operating environment |
Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) |
|
External dimension [W x D x H] | Approx. 46 x 66 x 27 mm (exclude protrusion) | |
Weight | Approx. 55 g |
• AC Current sensor
Item | Description | |
---|---|---|
GS-AC50A | Rated measuring current: 50 A AC (Length of cable to adapter is approx. 200 mm) | |
GS-AC100A | Rated measuring current: 100 A AC (Length of cable to adapter is approx. 200 mm) | |
GS-AC200A | Rated measuring current: 200 A AC (Length of cable to adapter is approx. 200 mm) |
Voltage & Temperature Input Terminal (GS-4VT) input module
Item | Description | |
---|---|---|
Type of measurement |
Analog voltage or Temperature, Logic (signal pattern) or Pulse (instant or accumulated count) |
|
Number of channel |
Voltage/Temperature: 4 channels (measurement type for channels can each be separately selected) Logic/pulse: 4 channels (measurement type for channels can be selected as set of 4 channels) |
|
Input method of voltage/temp. | Scans by the photo-MOS-relay, all channels isolated input | |
Measuring range of voltage | 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V F.S. and 1-5V F.S. | |
Measuring accuracy | 0.15 % of F.S. | |
Input impedance | 1 M ohms | |
Maximum input voltage |
Between positive ("+") and negative ("-") input terminal: 60 V Between negative ("-") terminal of channels: 60 V Between negative ("-") terminal of channel and "GND": 60 V |
|
Withstand voltage |
Between negative ("-") terminal of channels: 350 V p-p (1 minute) Between negative ("-") terminal of channel and "GND": 350 V p-p (1 minute) |
|
Measuring range of temperature | Thermocouple: K type -200 °C to 1370 °C, T type -200 °C to 400 °C | |
Measuring accuracy |
K type -200 ≤ TS ≤ -100 °C: ± (0.05% of reading + 2.0 °C) -100 < TS ≤ 1370 °C: ± (0.05% of reading + 1.0 °C) T type -200 ≤ TS ≤ -100 °C: ± (0.1% of reading + 1.5 °C) -100 < TS ≤ 400 °C: ± (0.1% of reading + 0.5 °C) Reference Junction Compensation (R.J.C.): ± 0.5 °C |
|
Burnout checking | Displaying warning when Thermocouple has failed | |
Unit of temperature measurement | Switchable °C and °F | |
Input of Logic/Pulse |
Input signal: Voltage or Dry contact signal Voltage input: 0 to +24V (common ground) Dry contact signal: Relay or Solid state relay Threshold voltage: Approx. +2.5V, Hysteresis: Approx. 0.5V (Status of the signal is changed in the 2V and the 2.5V.) |
|
Measuring rage of Pulse |
Instant count: up to 200 counts/sampling interval Accumulated count: up to 65535 counts (Accumulated value is reset by starting the data recording or pressing the QUIT key.) |
|
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Length of cable | Approx. 200 mm | |
Operating environment |
Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) |
|
External dimension [W x D x H] | Approx. 46 x 66 x 36 mm (exclude protrusion) | |
Weight | Approx. 85 g |
Thermistor Sensor Input Terminal (GS-4TSR) input module
Item | Description | |
---|---|---|
Type of measurement |
Temperature, Logic (signal pattern) or Pulse (instant or accumulated count) |
|
Number of channel |
Temperature: 4 channels (measurement type for channels can each be separately selected) Logic/pulse: 4 channels (measurement type for channels can be selected as set of 4 channels) |
|
Input method of temperature | Scans by the photo-MOS-relay, all channels non-isolated input | |
Temperature sensor | Thermistor (optional) | |
Measuring range |
Temperature: -40 to 120 °C (varies by the type of sensor) (Sensor GS-103AT-4P: -40 to 105 °C, GS-103JT-4P: -40 to 120 °C) |
|
Measuring accuracy |
• GL100 main body -40 ≤ TS < 0 °C: ± 0.7 °C 0 ≤ TS ≤ 35 °C: ± 0.2 °C 35 < TS ≤ 70 °C: ± 0.4 °C 70 < TS ≤ 120 °C: ± 1.0 °C • Thermistor sensor (GS-103AT-4P or GS-103JT-4P) Typical ± 0.4 °C |
|
Unit of temperature measurement | Switchable °C and °F | |
Input of Logic/Pulse |
Input signal: Voltage or Dry contact signal Voltage input: 0 to +24V (common ground) Dry contact signal: Relay or Solid state relay Threshold voltage: Approx. +2.5V, Hysteresis: Approx. 0.5V (Status of the signal is changed in the 2V and the 2.5V.) |
|
Measuring rage of Pulse |
Instant count: up to 200 counts/sampling interval Accumulated count: up to 65535 counts (Accumulated value is reset by starting the data recording or pressing the QUIT key.) |
|
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Length of cable | Approx. 200 mm | |
Operating environment |
Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) |
|
External dimension [W x D x H] | Approx. 46 x 66 x 36 mm (exclude protrusion) | |
Weight | Approx. 83 g |
Dual port adapter (GS-DPA) input module
Item | Description |
---|---|
Number of sensors | Two (2) sensors |
Connectable sensors |
GS-TH (Temp./Humidity), GS-CO2 (Carbon dioxide (CO2)), GS-LXUV (Illuminance & Ultraviolet) It is not able to connect two sensors of the same type. |
Length of cable | Approx. 200 mm |
Operating environment |
Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) |
External dimension [W x D x H] | Approx. 46 x 66 x 27 mm (exclude protrusion) |
Weight | Approx. 68 g |
Module Extension Cable (GS-EXC)
Item | Description | |
---|---|---|
Connectable input module |
All types of input module Cable is connected between the input module and the GL100. |
|
Length of cable | Approx. 1.5 m | |
Operating environment |
Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) |