Electrical Specifications
V AC (40-500Hz) Range 600.0 mV
6.000 V
60.00 V
600.0 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
Accuracy 3.0%±3 digit
1.0%±3 digit
V DC Range 6.000 V
60.00 V
600.0 V
Resolution 0.001 V
0.01 V
0.1 V
Accuracy 0.5%±3 digit
Resistance Ohms Range 400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy 0.5 %±3 digit
0.5 %±2 digit
0.5 %±2 digit
0.5 %±2 digit
0.5 %±2 digit
1.5%±3 digit
Capacitance Range 50.00 nF
500.0 nF
5.000 μF
50.00 μF
100.0 μF
Resolution 0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
Frequency 
(10 Hz – 100 kHz)
Range 50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
Resolution 0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
Duty Cycle Range 0.1 % to 99.9 %
Resolution 0.1 %
General Specifications
CAT Rating CAT III 600 V
V AC Range 600.0 V
V DC Range 600.0 V
Ohms Range 40.00 MΩ
Auto Shutoff Y
Continuity Y
Capacitor 100.0 μF
Frequency 100.0 kHz
Hold No
Duty Cycle Yes
Size 130 mm x 65 mm x 27mm 
Weight 160 g
Battery Two AAA
Warranty 1 year
Environmental Specifications
Operating Temperature 0 °C to +40 °C
Storage Temperature -30 °C to +60 °C
Operating Humidity Non condensing (<10 °C)
<=90% RH (at 10 °C to 30 °C)
<=75% RH (at 30 °C to 40 °C)
(Without Condensation)
Operating Humidity, 40 MΩ 80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C
Operating Altitude 2,000 meters
Storage Altitude 12,000 meters
IP Rating IP 40 per IEC 60529
Vibration Requirements MIL-PRF-28800F, Class 2
Drop Test Requirements -10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment
Shipping container drop per Fluke SOP 39.
EMI, RFI, EMC Must meet all applicable requirements in 
IEC/EN 61326-1
Absorption/Corrosion Per Fluke SOP 39.1
Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC
 

Model Name Description
Fluke 101 Includes:
  • Fluke 101 Basic Digital Multimeter
  • Tl75 Hard Point Test Lead Set
  • Two AAA Batteries (Installed)
Fluke 101 Kit Includes:
  • Fluke 101 Basic Digital Multimeter
  • Tl75 Hard Point Test Lead Set
  • Two AAA Batteries (Installed)
  • Smart Strap
Fluke 101 / i400E Clamp Bundle Includes:
  • Fluke 101 Basic Digital Multimeter
  • Fluke i400E AC Current Clamp
  • Tl75 Hard Point Test Lead Set

Current Clamps
Fluke i400E Fluke i400E AC Current Clamp

Test Leads
TL75 TL75 Hard Point™ Test Lead Set
 

 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version