- Digital Multimeter
- Analogue Multimeter
- Digital Clamp Meter
- Pen Type Digital Multimeter
- Digital Insulation Tester
- Analogue Insulation Tester
- Pocket Size Digital Multimeter
- Power meter
- Thermometer
- Volt Alert
- Voltage Tester
- Wireless Meter
- Moisture Meter
- Digital Earth Loop Meter
- Automotive Digital Multimeter
- Cable Tester
- Leakage Clamp Meter
- Measuring Instruments
- Soldering Irons and Switches
- Audio Equipments
- Data Logger
- Air Tester
- Clamp Sensors
- Earth Testers
- Laser Distance Meter
- LUX Meter
- Multi Function Testers
- Phase indicators
- RCD/PAT Testers
- Sound Meter
- Storage Cabinet
- Strength Meter
- Test Lead Set
Pacific Radio (M) Sdn Bhd
[16370-U]
80, Jalan Pasar, Pudu,
55100 Kuala Lumpur,
Malaysia.
+603-9221 8631 (6 Lines)
+603-9221 4216
+603-9221 3867
+6018-208 2618
+603-9221 8630
+603-9223 4109
Pacific Electronic (S) Pte Ltd
1 Rochor Canal Road,
#01-10/11/12,
Sim Lim Square,
Singapore 188504.
1 Rochor Canal Road,
#01-10/11/12,
Sim Lim Square,
Singapore 188504.
+65-6294 0851
+65-6337 1132
+65-6339 5884
+65-6337 1132
+65-6339 5884
+65-6339 8454
+65-6338 3609
+65-6338 3609
Fluke 107 Palm-sized Digital Multimeter
Previous | 37 / 54 | Next |
Accuracy Specifications | ||||
AC Volts (40 Hz to 500Hz)1 |
Range | Resolution | Accuracy | |
6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
1.0 % + 3 | ||
DC Volts |
6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
0.5 % + 3 | |
AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | |
Diode Test2 | 2.000 V | 0.001 V | 10 % | |
Resistance (Ohms) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
|
Capacitance3 |
50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
|
Frequency4 Hz (10 Hz – 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
0.1 % + 3 | |
Duty Cycle4 | 1 % to 99 % | 0.1 % | 1 % typical 5 | |
AC Current (40 Hz to 200 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |
DC Current |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |
|
||||
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
AC Volts | 600 V 1 | >10 MΩ <100 pF 2 |
>60 dB at dc, 50 Hz or 60 Hz |
− |
AC Millivolts | 600 mV | >1M, <100 pF | >80 dB at 50 Hz or 60 Hz | − |
DC Volts | 600 V 1 | >10 MΩ <100 pF |
>100 dB at dc, 50 Hz or 60 Hz |
>60 dB at 50 Hz or 60 Hz |
|
||||
General Specifications | ||||
Maximum Voltage Between any Terminal and Earth Ground | 600 V | |||
Display (LCD) | 6000 counts, updates 3/sec | |||
Battery Type | 2 AAA, NEDA 24A, IEC LR03 | |||
Battery Life | 200 hours minimum | |||
Temperature | ||||
Operating | 0 °C to 40 °C | |||
Storage | -30 °C to 60 °C | |||
Relative Humidity | ||||
Operating Humidity |
Non-condensing when <10°C ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C |
|||
Operating Humidity, 40 MΩ Range | ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C | |||
Altitude | ||||
Operating | 2000 m | |||
Storage | 12,000 m | |||
Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) | |||
Fuse Protection for Current Inputs |
11A, 1000V Fast Fuse, Fluke specified part only
|
|||
Size (HxWxL) | 142 mm x 69 mm x 28mm | |||
Weight | 200 g | |||
IP Rating | IEC 60529: IP 40 | |||
Safety | IEC 61010-1: 600 V CAT III, Pollution Degree 2 | |||
Electromagnetic Environment | IEC 61326-1: Portable | |||
Electromagnetic Compatibility | Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1 |
|