Fluke 117 Digital Multimeter
Specifications |
Maximum voltage between any terminal and earth ground |
600 V |
Surge protection |
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
Fuse for A input |
11 A, 1000 V FAST Fuse (Fluke PN 803293) |
Display |
Digital: |
6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating Temperature |
-10 °C to + 50 °C |
Storage Temperature |
-40 °C to + 60 °C |
Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life |
400 hours typical, without backlight |
Accuracy Specifications |
DC millivolts |
Range |
600.0 mV |
Resolution |
0.1 mV |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/Resolution |
6.000 V / 0.001 V |
Range/Resolution |
60.00 V / 0.01 V |
Range/Resolution |
600.00 V / 0.1 V |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
Auto volts |
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts1 true-rms |
Range |
600.0 mV |
Resolution |
0.1 mV |
Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms |
Range/Resolution |
6.000 V / 0.001 V |
Range/Resolution |
60.00 V / 0.01 V |
Range/Resolution |
600.0 V / 0.1 V |
Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
Continuity |
Range |
600 Ω |
Resolution |
1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
Ohms |
Range/Resolution |
600.0 Ω / 0.1 Ω |
Range/Resolution |
6.000 kΩ / 0.001 kΩ |
Range/Resolution |
60.00 kΩ / 0.01 kΩ |
Range/Resolution |
600.0 kΩ / 0.1 kΩ |
Range/Resolution |
6.000 MΩ / 0.001 MΩ |
Accuracy |
0.9 % + 1 |
Range/Resolution |
40.00 MΩ / 0.01 MΩ |
Accuracy |
5 % + 2 |
Diode Test |
Range/Resolution |
2.000 V / 0.001 V |
Accuracy |
0.9% + 2 |
Capacitance |
Range/Resolution |
1000 nF / 1 nF |
Range/Resolution |
10.00 μF / 0.01 μF |
Range/Resolution |
100.0 μF / 0.1 μF |
Range/Resolution |
9999 μF / 1 μF |
Range/Resolution |
100 μF to 1000 μF |
Accuracy |
1.9% + 2 |
Range/Resolution |
> 1000 μF |
Accuracy |
5% + 20% |
LoZ capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
AC amps true-rms (45 Hz to 500 Hz) |
Range/Resolution |
6.000 A / 0.001 A |
Range/Resolution |
10.00 A / 0.01 A |
Accuracy |
1.5% + 3
20 A continuous overload for 30 seconds max |
DC amps |
Range/Resolution |
6.000 A / 0.001 A |
Range/Resolution |
10.00 A / 0.01 A |
Accuracy |
1.0% + 3
20 A continuous overload for 30 seconds max |
Hz (V or A input)2 |
Range/Resolution |
99.99 Hz / 0.01 Hz |
Range/Resolution |
999.99 Hz / 0.1 Hz |
Range/Resolution |
9.999 Hz / 0.001 Hz |
Range/Resolution |
50.00 Hz / 0.01 Hz |
Accuracy |
0.1% + 2 |
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
Mechanical & General Specifications |
Size |
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
Weight |
550 g |
Warranty |
3 years |
Fluke 323 True-rms Clamp Meter
Specifications |
AC current |
Range 400.0 A |
|
Accuracy |
2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz) |
AC voltage |
Range |
600.0 V |
Accuracy |
1.5 % ± 5 digits |
DC voltage |
Range |
600.0 V |
Accuracy |
1.0 % ± 5 digits |
Resistance |
Range |
400.0 Ω/ 4000 Ω |
Accuracy |
1.0 % ± 5 digits |
Continuity |
≤ 70 Ω |
AC response |
True-rms |
Data hold |
Yes |
Size |
H x W x D (mm) |
207 x 75 x 34 |
Max wire diameter |
30 mm (600 MCM) |
Weight |
265 g |
Category rating |
CAT III 600 V
CAT IV 300 V |
Warranty |
Two-year |
|
|
|
|