Fluke 116 HVAC Multimeter with Temperature and Microamps
Specifications |
Maximum voltage between any terminal and earth ground |
600 V |
Surge protection |
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
Display |
6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating Temperature |
-10 °C to + 50 °C |
Storage Temperature |
-40 °C to + 60 °C |
Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life |
400 hours typical, without backlight |
Accuracy Specifications |
DC millivolts |
Range |
600.0 mV |
Resolution |
0.1 mV |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/Resolution |
6.000 V / 0.001 V |
Range/Resolution |
60.00 V / 0.01 V |
Range/Resolution |
600.00 V / 0.1 V |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
Auto volts |
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts1 true-rms |
Range |
600.0 mV |
Resolution |
0.1 mV |
Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms |
Range/Resolution |
6.000 V / 0.001 V |
Range/Resolution |
60.00 V / 0.01 V |
Range/Resolution |
600.0 V / 0.1 V |
Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
Continuity |
Range |
600 Ω |
Resolution |
1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
Ohms |
Range/Resolution |
600.0 Ω / 0.1 Ω |
Range/Resolution |
6.000 kΩ / 0.001 kΩ |
Range/Resolution |
60.00 kΩ / 0.01 kΩ |
Range/Resolution |
600.0 kΩ / 0.1 kΩ |
Range/Resolution |
6.000 MΩ / 0.001 MΩ |
Accuracy |
0.9 % + 1 |
Range/Resolution |
40.00 MΩ / 0.01 MΩ |
Accuracy |
1.5 % + 2 |
Diode Test |
Range/Resolution |
2.000 V / 0.001 V |
Accuracy |
0.9% + 2 |
Capacitance |
Range/Resolution |
1000 nF / 1 nF |
Range/Resolution |
10.00 μF / 0.01 μF |
Range/Resolution |
100.0 μF / 0.1 μF |
Range/Resolution |
9999 μF / 1 μF |
Range/Resolution |
100 μF to 1000 μF |
Accuracy |
1.9% + 2 |
Range/Resolution |
> 1000 μF |
Accuracy |
5% + 20% |
LoZ capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
Temperature2 (Type-K thermocouple) |
Range/Resolution |
-40 °C to 400 °C / 0.1 °C |
Accuracy |
1% + 102 |
Range/Resolution |
-40 °F to 752 °F / 0.2 °F |
Accuracy |
1% + 182 |
AC μamps true-rms (45 Hz to 500 Hz) |
Range/Resolution |
600.0 μA / 0.1 μA |
Accuracy |
1.0% + 2 |
DC μamps |
Range/Resolution |
600.0 μA / 0.1 μA |
Accuracy |
1.0% + 2 |
Hz (V or A input)2 |
Range/Resolution |
99.99 Hz / 0.01 Hz |
Range/Resolution |
999.99 Hz / 0.1 Hz |
Range/Resolution |
9.999 Hz / 0.001 Hz |
Range/Resolution |
50.00 Hz / 0.01 Hz |
Accuracy |
0.1% + 2 |
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
Mechanical & General Specifications |
Size |
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
Weight |
550 g |
Warranty |
3 years |
Fluke 62 MAX+ Infrared Thermometer
Specifications |
Temperature Range
|
-30 °C to 650 °C (-22 °F to 1202 °F) |
Accuracy |
±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0 |
Response Time (95%) |
Fluke 62+ MAX |
<300 ms (95% of reading) |
Spectral Response |
8 to 14 microns |
Emissivity |
0.10 to 1.00 |
Optical Resolution
|
12:1 (calculated at 90% energy) |
Display Resolution |
0.1 °C (0.2 °F) |
Repeatability of Readings |
±0.5% of reading or <±0.5 °C (1 °F), whichever is greater |
Power |
AA battery |
Battery Life |
8 hours with laser and backlight on |
Physical Specifications |
Weight |
255 g (8.99 oz) |
Size |
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |
Operating Temperature |
0 °C to 50 °C (32 °F to 122 °F) |
Storage Temperature |
-20 °C to 60 °C (-4 °F to 140 °F), (without battery) |
Operating Humidity |
10 % to 90 % RH non-condensing at 30 °C (86 °F) |
Operating Altitude |
2000 meters above mean sea level |
Storage Altitude |
12,000 meters above mean sea level |
IP Rating |
IP 54 per IEC 60529 |
Drop Test |
3 meters |
Vibration and Shock |
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
EMC |
EN 61326-1:2006 EN 61326-2:2006 |
Standards and Agency Approval
|
Compliance |
EN/IEC 61010-1: 2001 |
Laser Safety |
FDA and EN 60825-1 Class II |
|
|
|
|