Fluke 572-2 High-Temperature Infrared Thermometer

Previous 14 / 16 Next

Fluke 572-2 High-Temperature Infrared Thermometer FLUKE Thermometer Fluke 572-2 High-Temperature Infrared Thermometer FLUKE Thermometer


Infrared Measurements
Infrared temperature range -30 °C to 900 °C (-22 °F to 1652 °F)
IR accuracy (calibration geometry with ambient temperature 23 °C ± 2 °C) ≥ 0°C: ± 1°C or ± 1 % of the reading, whichever is greater
≥-10 °C to <0 °C: ±2°C
<-10°C: ±3 °C

≥32°F: ± 2°F or ± 1% of the reading, whichever is greater
≥14 °F to <32 °F: ±4 °F
<14 °F: ±6 °F
IR repeatability ±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater
Display resolution 0.1 °C / 0.1 °F
Distance: Spot 60:1 (calculated at 90 % energy)
Minimum spot size 19 mm
Laser sighting Offset dual laser, output <1 mW
Spectral response 8 μm to 14 μm
Response time (95 %) <500 ms
Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials

Contact Measurements
K-type thermocouple input temperature range -270 °C to 1372 °C (-454 °F to 2501 °F)
K-type thermocouple input accuracy (with ambient temperature 23 °C ± 2 °C) <-40 °C: ±(1 °C + 0.2 °/1 °C)
≥-40 °C: ±1 % or 1 °C, whichever is greater
<-40 °F: ±(2 °F + 0.2 °/1 °F)
≥-40 °F: ±1 % or 2 °F, whichever is greater
K-type thermocouple 0.1 °C/0.1 °F
K-type thermocouple repeatability ±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater

Measurement Options
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Switchable celsius and fahrenheit Yes
Backlight Two levels, normal and extra bright for darker environments
Probe input K-type thermocouple simultaneous display of probe and IR temperature
Trigger lock Yes
Data storage 99 points
Display Dot matrix 98 x 96 pixels with function menus
Communication USB 2.0

K-Type Thermocouple Specifications
Measurement range (bead probe) -40 °C to 260 °C (-40 °F to 500 °F)
Accuracy ±1.1 °C (±2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F). Typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)
Cable length 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination

General Specifications
Safety and compliance IEC 60825-1 
FDA Laser Class II 
IEC 61326-1 
CE Complaint 
CMC # 01120009
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F)
Relative humidity 10 % to 90 % RH non-condensing up to 30 °C (86 °F)
Operating altitude 2000 meters above mean sea level
Weight 0.322 kg (0.7099 lb)
Power 2 AA batteries
Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on)
 

Model Name Description
Fluke 572-2

High-Temperature Infrared Thermometer
Includes:

  • K-type thermocouple bead probe
  • Durable hard case
  • USB 2.0 computer interface cable

Temperature
80PJ-1 80PJ-1 Bead Probe
80PK-1 80PK-1 Bead Probe
80PK-11 80PK-11 Type-K Flexible Cuff Thermocouple Temperature Probe
80PK-25 80PK-25 SureGrip™ Piercing Temperature Probe
80PK-26 80PK-26 SureGrip™ Tapered Temperature Probe
80PK-9 80PK-9 General Purpose Probe
80PK-27 80PK-27 SureGrip™ Industrial Surface Temperature Probe