Kyoritsu 3126 High Voltage Insulation Tester

Previous 3 / 8 Next

Kyoritsu 3126 High Voltage Insulation Tester KYORITSU Digital Insulation Tester Kyoritsu 3126 High Voltage Insulation Tester KYORITSU Digital Insulation Tester


Basic Features :

Short-Circuit Current up to 5mA
Wide range measurements from 500V to 5000V and up to 1TΩ
Large digital display with Bar Graph indication and white LED back light
Polarization Index measurement (PI), Dielectric Absorption Ratio (DAR)
Filter function reduces noise interference for obtaining stable measurement
Indication of Output voltage and Discharge voltage
Auto-discharge function and Output voltage warning function
Auto power off and Battery Indicator
Safety standard IEC 61010-1 CAT III 600V

Backlight 3126 500V/1000V/2500V/5000V

 
Range Insulation resistance Voltage
measurement
500V 1000V 2500V 5000V AC/DC
Measuring range 0.0 - 99.9MΩ
100 - 999MΩ
0.0 - 99.9MΩ
100 - 999MΩ
1.00 - 1.99GΩ
0.0 - 99.9MΩ
100 - 999MΩ
1.00 - 9.99GΩ
10.0 - 99.9GΩ
0.0 - 99.9MΩ
100 - 999MΩ
1.00 - 9.99GΩ
10.0 - 99.9GΩ
100 - 1000GΩ
(1TΩ)
30 - 600V
AC/DC
(50/60Hz)
Accuracy |±5%rdg |±3dgt |±5%rdg |±3dgt |±5%rdg |±3dgt |±5%rdg |±3dgt
|±20%(100GΩ or more)
|±2%rdg |±3dgt
Short Circuit Current Max. 5mA -------
Rated test Current 1mA to 1.2mA
at 0.5MΩ load
1mA to 1.2mA
at 1MΩ load
1mA to 1.2mA
at 2.5MΩ load
1mA to 1.2mA
at 5MΩ load
-------
Open circuit voltage 500VDC
+30%
-0%
1000VDC
+20%
-0%
2500VDC
+20%
-0%
5000VDC
+20%
-0%
-------
Maximum display 999 Counts (1000 counts only at 1000GΩ) 630 Counts
Current consumption 1000mA approx. (During measurement) 110mA approx.
Withstand Voltage 5320V AC for 5 seconds
Applicable standard IEC 61010-1 CAT III 600V Pollution degree 2
IEC 61010-031, IEC 61326
Power source DC12V : LR14×8 pcs.
Dimensions 205(L) × 152(W) × 94(D)mm
Weight 1.8kg approx.
Accessories 7165A (Line probe), 7224A (Earth cord), 7225A (Guard cord)
8019 (Hook type prod), 9159 (Hard case)
LR14 (Alkaline battery size C) × 8, Instruction manual
Optional 7168A (Line probe with alligator clip)
7253 (Longer Line probe with alligator clip)