- Automatically measures volts ac and volts dc with precise digital resolution
- Displays resistance to 1000Ω
- Easy and accurate OpenJaw™ current measurement
- Continuity beeper
- Compact design with neat probe storage
- Rugged enough to withstand a 10-foot (3m) drop
- Detachable SlimReach™ probe tips are customized for national electrical standards
- Test leads accept Fluke accessory test clips
- 600V model
- Can stay connected much longer than solenoid type tester
- Auto off mode to conserve battery life
- Optional holster attaches to a belt and neatly stows test leads
- AC current
- Display hold
Safety Conformance
All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.
| Specifications | |
| Jaw opening | 12.9 mm (0.5 in) |
| Max wire size | 1/0 THHN Cable |
| Current range ac rms | 0 to 100.0 A |
| Accuracy ac current (50/60 Hz) | 3 % ± 3 counts |
| AC Response | Averaging |
| Voltage range ac | 0 to 600 V |
| Accuracy ac voltage | 1.5 % ± 2 counts |
| Voltage range dc | 0 to 600 V |
| Accuracy dc voltage | 1 % ± 1 count |
| Resistance range | 0 to 1000 Ω |
| Continuity beeper threshold | On at <25 Ω, off at >400 Ω |
| Volts indicator LED threshold | Guaranteed on by 30 V ac |
| Environmental Specifications | |
| Operating Temperature | -10 °C to 50 °C |
| Storage Temperature | -30 °C to 60 °C |
| Humidity (Without Condensation) |
0 % to 95 % (5 °C to 30 °C); 0 % to 75 % (30 °C to 40 °C); 0 % to 45 % (40 °C to 50 °C) |
| Dust/water resistance | Yes |
| Operating Altitude | 2000 meters max |
| Temperature Coefficient | 0.1 x (specified accuracy)/°C (<18 °C or >28 °C) |
| Safety Specifications | |
| Overvoltage category | CAT III 600 V ac/dc (EN61010-1) |
| Agency Approvals | UL, CSA, and VDE |
| Maximum voltage | Between any terminal and earth ground |
| Mechanical and General Specifications | |||||||||||
| Size | 30.5 mm x 51 mm x 203 mm | ||||||||||
| Weight | 300g | ||||||||||
| Warranty | Two-years | ||||||||||
| Battery Life | 200 hour zinc chloride, 400 hour alkaline | ||||||||||
| Battery type | 2 x AA | ||||||||||
| Low battery indicator | Yes | ||||||||||
| Current sensor opening | 12.9 mm | ||||||||||
| Calibration cycle | 1 year | ||||||||||
| Test leads |
|
||||||||||